©2025 Stanford Medicine
A Clinical Trial to Assess the Agent Paclitaxel Coated PTCA Balloon Catheter for the Treatment of Subjects With In-Stent Restenosis (ISR) - Long Lesion Cohort
Not Recruiting
Trial ID: NCT06492174
Purpose
The purpose of the AGENT IDE study is to assess the safety and effectiveness of the Agent Paclitaxel Coated PTCA Balloon Catheter in patients with in-stent restenosis (ISR) of a previously treated lesion of up to 36 mm in length (by visual estimate) in a native coronary artery 2.0 mm to 4.0 mm in diameter.
Official Title
AGENT IDE: A Prospective, Randomized (2:1), Multicenter Trial to Assess the Safety and Effectiveness of the AgentTM Paclitaxel Coated PTCA Balloon Catheter for the Treatment of Subjects With In-Stent Restenosis (ISR)
Stanford Investigator(s)
Jennifer Tremmel
Susan P. and Riley P. Bechtel Medical Director and Associate Professor of Medicine (Cardiovascular Medicine)
Eligibility
Clinical Inclusion Criteria:
* Subject must be at least 18 years of age
* Subject (or legal guardian) understands the trial requirements and the treatment procedures, and provides written informed consent before any trial-specific tests or procedures are performed
* Subject is eligible for percutaneous coronary intervention (PCI)
* Subject is willing to comply with all protocol-required follow-up evaluation
* Women of child-bearing potential must agree to use a reliable method of contraception from the time of screening through 12 months after the index procedure
Angiographic Inclusion Criteria (visual estimate)
* In-stent restenosis in a lesion previously treated with either a drug-eluting stent or bare metal stent, located in a native coronary artery with a visually estimated reference vessel diameter (RVD) \> 2.0 mm and ≤ 4.0 mm.
* Target lesion length must be ≤ 36 mm (by visual estimate) and must be covered by only one balloon.
* Target lesion must have visually estimated stenosis \> 50% and \< 100% in symptomatic patients (\>70% and \<100% in asymptomatic patients) prior to lesion pre-dilation.
* Target lesion must be successfully pre-dilated.
Note: Successful predilation/pretreatment refers to dilation with a balloon catheter of appropriate length and diameter, or pretreatment with directional or rotational coronary atherectomy, laser or cutting/scoring balloon with no greater than 50% residual stenosis and no dissection greater than National Heart, Lung, Blood Institute (NHLBI) type C. Thrombolysis in Myocardial Infarction (TIMI) grade flow in the target lesion must be \>2
* If a non-target lesion is treated, it must be treated first and must be deemed a success.
Note: Successful treatment of a non-target lesion is defined as a residual stenosis of ≤ 30% in 2 near-orthogonal projections with TIMI 3 flow, as visually assessed by the physician, without the occurrence of prolonged chest pain or ECG changes consistent with MI.
Clinical Exclusion Criteria:
* Subject has other serious medical illness (e.g. cancer, congestive heart failure) that may reduce life expectancy to less than 24 months.
* Subject has current problems with substance abuse (e.g. alcohol, cocaine, heroin, etc.).
* Subject has planned procedure that may cause non-compliance with the protocol or confound data interpretation.
* Subject is participating in another investigational drug or device clinical study that has not reached its primary endpoint.
* Subject intends to participate in another investigational drug or device clinical study within 12 months after the index procedure.
* Woman who is pregnant or nursing. (A pregnancy test must be performed within 7 days prior to the index procedure, except for women who definitely do not have child-bearing potential.)
* Left ventricular ejection fraction known to be \< 25%.
* Subject had PCI or other coronary interventions within the last 30 days.
* Planned PCI or CABG after the index procedure.
* STEMI or QWMI \<72h prior to the index procedure.
* Cardiogenic shock (SBP \< 80 mmHg requiring inotropes, IABP or fluid support).
* Known allergies against paclitaxel or other components of the used medical devices.
* Known hypersensitivity or contraindication for contrast dye that in the opinion of the investigator cannot be adequately pre- medicated.
* Intolerance to antiplatelet drugs, anticoagulants required for procedure.
* Platelet count \< 100k/mm3 (risk of bleeding) or \> 700k/mm3.
* Subject with renal insufficiency (creatinine ≥2.0 mg/dl) or failure (dialysis dependent).
* Subject has suspected or proven COVID-19 at present or within the past 4 weeks with resolution of symptoms.
Angiographic Exclusion Criteria (visual estimate)
* Target lesion is located within a bifurcation with planned treatment of side branch vessel.
* Target lesion is located within a saphenous vein or arterial graft.
* Thrombus present in the target vessel
* \> 50% stenosis of an additional lesion proximal or clinically significant distal (\>2.0mm RVD) to the target lesion.
* Patient with unprotected left main coronary artery disease. (\>50% diameter stenosis)
Intervention(s):
device: AGENT DCB 40 mm
Not Recruiting
Contact Information
Stanford University
School of Medicine
300 Pasteur Drive
Stanford,
CA
94305
Jennifer Tremmel, MD